01672nas a2200181 4500000000100000008004100001100001500042700001200057700001700069700001800086700001600104245007700120250001500197300001000212490000700222520121000229020005101439 2015 d1 aBellomo R.1 aCass A.1 aGallagher M.1 aMartensson J.1 aKaukonen K.00aFemoral Access and Delivery of Continuous Renal Replacement Therapy Dose a2015/10/21 a11-170 v413 a
AIMS: The study aims to describe the use of dialysis catheters in critically ill patients treated with continuous renal replacement therapy (CRRT) and to study the impact of femoral versus non-femoral access on CRRT dose. METHODS: Statistical analysis and predictive modelling of data from the Randomized Evaluation of Normal vs. Augmented Level renal replacement therapy trial. RESULTS: The femoral vein was the first access site in 937 (67%) of 1,399 patients. These patients had higher Acute Physiology and Chronic Health Evaluation and Sequential Organ Failure Assessment scores (p = 0.009) and lower pH (p < 0.001) but similar mortality to patients with non-femoral access (44 vs. 45%; p = 0.63). Lower body weight was independently associated with femoral access placement (OR 0.97, 95% CI 0.96-0.98). Femoral access was associated with a 1.03% lower CRRT dose (p = 0.05), but a 4.20% higher dose was achieved with 13.5 Fr catheters (p = 0.03). CONCLUSIONS: Femoral access was preferred in lighter and sicker patients. Catheter gauge had greater impact than catheter site in CRRT dose delivery. Video Journal Club "Cappuccino with Claudio Ronco" at http://www.karger.com/?doi=439581.
a1421-9735 (Electronic)