TY - JOUR AU - Bellomo R. AU - Cass A. AU - Gallagher M. AU - Martensson J. AU - Kaukonen K. AB -

AIMS: The study aims to describe the use of dialysis catheters in critically ill patients treated with continuous renal replacement therapy (CRRT) and to study the impact of femoral versus non-femoral access on CRRT dose. METHODS: Statistical analysis and predictive modelling of data from the Randomized Evaluation of Normal vs. Augmented Level renal replacement therapy trial. RESULTS: The femoral vein was the first access site in 937 (67%) of 1,399 patients. These patients had higher Acute Physiology and Chronic Health Evaluation and Sequential Organ Failure Assessment scores (p = 0.009) and lower pH (p < 0.001) but similar mortality to patients with non-femoral access (44 vs. 45%; p = 0.63). Lower body weight was independently associated with femoral access placement (OR 0.97, 95% CI 0.96-0.98). Femoral access was associated with a 1.03% lower CRRT dose (p = 0.05), but a 4.20% higher dose was achieved with 13.5 Fr catheters (p = 0.03). CONCLUSIONS: Femoral access was preferred in lighter and sicker patients. Catheter gauge had greater impact than catheter site in CRRT dose delivery. Video Journal Club "Cappuccino with Claudio Ronco" at http://www.karger.com/?doi=439581.

AD - Australian and New Zealand Intensive Care Research Centre (ANZIC-RC), Department of Epidemiology and Preventive Medicine, Monash University, The Alfred Centre, Level 6, Melbourne, Vic., Australia. AN - 26485539 BT - Blood Purification DP - NLM ET - 2015/10/21 LA - Eng LB - AUS
R&M
FY16 M1 - 1-3 N1 - Bellomo, Rinaldo
Martensson, Johan
Lo, Serigne
Kaukonen, Kirsi-Maija
Cass, Alan
Gallagher, Martin
RENAL study investigators and the Australian and New Zealand Intensive Care Clinical Trials Group
Blood Purif. 2015 Oct 20;41(1-3):11-17. N2 -

AIMS: The study aims to describe the use of dialysis catheters in critically ill patients treated with continuous renal replacement therapy (CRRT) and to study the impact of femoral versus non-femoral access on CRRT dose. METHODS: Statistical analysis and predictive modelling of data from the Randomized Evaluation of Normal vs. Augmented Level renal replacement therapy trial. RESULTS: The femoral vein was the first access site in 937 (67%) of 1,399 patients. These patients had higher Acute Physiology and Chronic Health Evaluation and Sequential Organ Failure Assessment scores (p = 0.009) and lower pH (p < 0.001) but similar mortality to patients with non-femoral access (44 vs. 45%; p = 0.63). Lower body weight was independently associated with femoral access placement (OR 0.97, 95% CI 0.96-0.98). Femoral access was associated with a 1.03% lower CRRT dose (p = 0.05), but a 4.20% higher dose was achieved with 13.5 Fr catheters (p = 0.03). CONCLUSIONS: Femoral access was preferred in lighter and sicker patients. Catheter gauge had greater impact than catheter site in CRRT dose delivery. Video Journal Club "Cappuccino with Claudio Ronco" at http://www.karger.com/?doi=439581.

PY - 2015 SN - 1421-9735 (Electronic)
0253-5068 (Linking) SP - 11 EP - 17 T2 - Blood Purification TI - Femoral Access and Delivery of Continuous Renal Replacement Therapy Dose VL - 41 Y2 - FY16 ER -